using Godot;
|
||
|
using System;
|
||
|
|
||
|
namespace EGFramework.Examples.ModbusDebugTool{
|
||
|
public partial class ViewModbusItem : Node,IEGFramework
|
||
|
{
|
||
|
public DataModbusItem DataModbusItem { set; get; }
|
||
|
|
||
|
public Label ID { set; get; }
|
||
|
|
||
|
public Label Title { set; get; }
|
||
|
|
||
|
public Label Value { set; get; }
|
||
|
|
||
|
public LineEdit InputData { set; get; }
|
||
|
|
||
|
private bool IsLoadUI { set; get; }
|
||
|
|
||
|
public override void _Ready()
|
||
|
{
|
||
|
|
||
|
}
|
||
|
|
||
|
public void LoadUI(){
|
||
|
if(!IsLoadUI){
|
||
|
Title = this.GetNode<Label>("Title");
|
||
|
Value = this.GetNode<Label>("Value");
|
||
|
ID = this.GetNode<Label>("ID");
|
||
|
InputData = this.GetNode<LineEdit>("WriteEdit");
|
||
|
InputData.Text = "0";
|
||
|
IsLoadUI = true;
|
||
|
}
|
||
|
}
|
||
|
|
||
|
public void LoadData(DataModbusItem data){
|
||
|
LoadUI();
|
||
|
this.DataModbusItem = data;
|
||
|
Title.Text = data.Type.ToString();
|
||
|
ID.Text = data.DeviceAddress+"-"+data.RegisterAddress;
|
||
|
Value.Text = "";
|
||
|
}
|
||
|
public void OnModifyItem(){
|
||
|
this.OnModifyEdit(DataModbusItem);
|
||
|
}
|
||
|
|
||
|
public void WriteValue(){
|
||
|
try
|
||
|
{
|
||
|
IRequest WriteRequest;
|
||
|
switch(DataModbusItem.Type){
|
||
|
case ModbusRegisterType.HoldingRegister:
|
||
|
WriteRequest = new ModbusRTU_WriteSingleHoldingRegister
|
||
|
(DataModbusItem.DeviceAddress,DataModbusItem.RegisterAddress,ushort.Parse(InputData.Text));
|
||
|
this.AppendMessage("【发送-"+DataModbusItem.SerialPort+"】 "+WriteRequest.ToProtocolByteData().ToStringByHex());
|
||
|
this.EGSendMessage(WriteRequest,DataModbusItem.SerialPort,ProtocolType.SerialPort);
|
||
|
break;
|
||
|
}
|
||
|
}
|
||
|
catch (System.Exception ex)
|
||
|
{
|
||
|
GD.PrintErr(ex);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
public void OnDeleteItem(){
|
||
|
if(this.EGGetObject<DataModbus>().Items.ContainsKey(DataModbusItem.GetKey())){
|
||
|
this.EGGetObject<DataModbus>().Items.Remove(DataModbusItem.GetKey());
|
||
|
}
|
||
|
this.EGSave().SetDataToFile(this.EGGetObject<DataModbus>());
|
||
|
this.GetNode<ViewMenu>("/root/Menu").RefreshSaveData();
|
||
|
}
|
||
|
|
||
|
public void GetValue(){
|
||
|
IRequest ReadRequest;
|
||
|
switch(DataModbusItem.Type){
|
||
|
case ModbusRegisterType.HoldingRegister:
|
||
|
ReadRequest = new ModbusRTU_ReadHoldingRegisters
|
||
|
(DataModbusItem.DeviceAddress,DataModbusItem.RegisterAddress,1);
|
||
|
this.AppendMessage("【发送-"+DataModbusItem.SerialPort+"】 "+ReadRequest.ToProtocolByteData().ToStringByHex());
|
||
|
this.EGSendMessage(ReadRequest,DataModbusItem.SerialPort,ProtocolType.SerialPort);
|
||
|
this.EGSerialPort().SetExpectReceivedDataLength(6);
|
||
|
break;
|
||
|
}
|
||
|
this.GetNode<ViewMenu>("/root/Menu").OnModbusRTUGet.Register(OnValueGet);
|
||
|
}
|
||
|
|
||
|
public void OnValueGet(ModbusRTU_Response e){
|
||
|
if((int)e.FunctionType == (int)DataModbusItem.Type && DataModbusItem.DeviceAddress == e.DeviceAddress){
|
||
|
switch(DataModbusItem.Type){
|
||
|
case ModbusRegisterType.HoldingRegister:
|
||
|
this.Value.Text = e.HoldingRegister[0].ToString();
|
||
|
break;
|
||
|
}
|
||
|
}
|
||
|
this.GetNode<ViewMenu>("/root/Menu").OnModbusRTUGet.UnRegister(OnValueGet);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
}
|